Safety & Infection Control

Maintaining Standard Precautions and Sterilizing Equipment

Hand hygiene, PPE, and instrument sterilization — the Safety & Infection Control tasks that protect patients and staff from cross-contamination.

7 steps·4 quality checkpoints·4 common mistakes

Note:the CMA (AAMA) exam has no hands-on or oral evaluation component — it's 200 written multiple-choice questions. This guide describes the real on-the-job task so you understand the knowledge the written exam tests, not a skills test you'll be scored on in person.

Step-by-Step Procedure

  1. 1

    Perform hand hygiene before and after every patient contact, and before/after glove use — gloves are not a substitute for hand hygiene.

  2. 2

    Select PPE appropriate to the task: gloves for any contact with blood or body fluids, with a mask, gown, or face shield added based on the expected exposure risk.

  3. 3

    After a procedure, separate reusable instruments by contamination level and pre-clean (rinse/scrub) them before sterilization — items cannot be effectively sterilized with visible debris still on them.

  4. 4

    Load the autoclave correctly (proper spacing for steam penetration, pouches oriented per manufacturer instructions) rather than packing it as full as possible.

  5. 5

    Run the correct cycle (time, temperature, pressure) for the load and instrument type, and verify the cycle completed successfully using the autoclave's indicators.

  6. 6

    Use biological indicators on the schedule your office protocol requires (commonly weekly) to confirm the autoclave is actually achieving sterilization, not just running a cycle.

  7. 7

    Store sterilized instruments in their sealed pouches, checking expiration/integrity dates before use, and discard anything with a torn or compromised seal.

Quality Checkpoints

  • ✓

    Hand hygiene happens before AND after every patient contact and every glove use — not glove use in place of hand hygiene.

  • ✓

    Instruments are pre-cleaned of visible debris before being loaded for sterilization.

  • ✓

    The autoclave load is spaced correctly, not overpacked, so steam can reach every surface.

  • ✓

    Biological indicator testing is done on schedule and the results are documented, not assumed.

Common Mistakes

  • ⚠

    Treating gloves as a replacement for hand hygiene instead of an addition to it.

  • ⚠

    Overpacking the autoclave to get through instruments faster, which can prevent proper steam penetration and leave items under-sterilized.

  • ⚠

    Skipping biological indicator testing because "the autoclave has always worked fine" — equipment failure isn't always obvious from the outside.

  • ⚠

    Using a sterilized pouch with a torn seal because the instrument "looks clean," instead of discarding it and reprocessing.

On-the-Job Tips

  • →

    Build hand hygiene into the physical motion of entering and leaving a room — tying it to a location, not just a mental reminder, makes it automatic.

  • →

    Keep a visible log of biological indicator results — if your office can't immediately show when the autoclave was last verified, that's worth flagging, not assuming is fine.